APSR2026-389

 
Late-Breaking
Submitted
Poster Presentation
 
AP05-019
P122
 
Format: PPTX Only
https://storage.unitedwebnetwork.com/files/1285/1210886-46904-APSR ABPP_433959.pdf
Format: PDF Only
12. Bronchoscopy and Interventional Techniques
10

No more than 15 authors can be listed.
Please ensure the authors are listed in the right order.
If there are multiple affiliations, please use the "+" button next to "Select Country/Region" to add additional affiliation fields.

Ying Hoey Lim * Ampang Hospital    Respiratory Unit, Department of Internal Medicine Selangor Malaysia
Wei Yin Lee - Ampang Hospital    Respiratory Unit, Department of Internal Medicine Selangor Malaysia
Joanne Cho Ee Tan - Ampang Hospital    Respiratory Unit, Department of Internal Medicine Selangor Malaysia
Nur Alya Shafiqah Abd Aziz - Ampang Hospital    Respiratory Unit, Department of Internal Medicine Selangor Malaysia
Muhammad Najmi Rosly - Ampang Hospital    Respiratory Unit, Department of Internal Medicine Selangor Malaysia
Yu Wei Cheah - Ampang Hospital    Respiratory Unit, Department of Internal Medicine Selangor Malaysia
Zuhri Zainuddin - Ampang Hospital    Respiratory Unit, Department of Internal Medicine Selangor Malaysia
Kar Seng Tan - Ampang Hospital    Respiratory Unit, Department of Internal Medicine Selangor Malaysia
Thian Hao Ho - Ampang Hospital    Respiratory Unit, Department of Internal Medicine Selangor Malaysia
Sze Kye Teoh - Ampang Hospital    Respiratory Unit, Department of Internal Medicine Selangor Malaysia
 
 
 
 
 
Presenting Author Details
Ying Hoey
Lim
yinghoey@gmail.com
+60124056030
31-40
Malaysia
Case Report
Autologous blood patch pleurodesis for refractory persistent air leak: A practical and cost-effective approach
Maximum 25 words
Abstract Content
 
 
 
 
Persistent air leak (PAL) is a recognised complication of pneumothorax and is associated with prolonged hospitalisation, increased healthcare utilisation and the potential need for surgical referral. Autologous blood patch pleurodesis (ABPP) is a minimally invasive bedside technique with growing evidence supporting its efficacy. We describe our experience using ABPP for PAL in a district hospital setting without on-site cardiothoracic services.
Six patients (median age 44.5 years, range 20–67; four male) underwent ABPP between May and December 2025 for persistent air leak following pneumothorax. The underlying causes included secondary spontaneous pneumothorax related to infection and structural lung disease. The volume of autologous blood instilled ranged from 70 to 160 mL. Successful cessation of air leak was achieved in all patients (100%; 95% CI 54.1–100%). Time to leak closure ranged from 24 hours to 7 days. Chest drains were removed within one week of the procedure in all cases. No immediate complications including empyema or significant fever were observed. Five patients were discharged well. One patient later died due to a contralateral pneumothorax, which was considered unrelated to the procedure. No recurrence of air leak was documented during one-month follow-up.
ABPP is a safe, effective and practical intervention for PAL that can be performed at the bedside, potentially reducing the need for surgical referral. It is particularly valuable in patients who are poor surgical candidates or in resource-limited settings. Although limited by small sample size and retrospective design, our findings support the use of ABPP as a viable treatment strategy in non-tertiary centres without cardiothoracic services.
 
 