APSR2026-404

Yes
Late-Breaking
Submitted
Poster Presentation
 
AP09-005
P131
 
Format: PPTX Only
https://storage.unitedwebnetwork.com/files/1285/1211555-46904-APSR-404_439622.pdf
Format: PDF Only
14. Respiratory Structure and Function
3

No more than 15 authors can be listed.
Please ensure the authors are listed in the right order.
If there are multiple affiliations, please use the "+" button next to "Select Country/Region" to add additional affiliation fields.

Nuri Indahwati * Faculty of Medicine Universitas Indonesia – Persahabatan Hospital National Respiratory Center Department of Pulmonology and Respiratory Medicine Jakarta Timur Indonesia
Triya Damayanti - Faculty of Medicine Universitas Indonesia – Persahabatan Hospital National Respiratory Center Department of Pulmonology and Respiratory Medicine Jakarta Timur Indonesia
Budhi Antariksa - Faculty of Medicine Universitas Indonesia – Persahabatan Hospital National Respiratory Center Department of Pulmonology and Respiratory Medicine Jakarta Timur Indonesia
 
 
 
 
 
 
 
 
 
 
 
 
Presenting Author Details
Nuri
Indahwati
nuri.indahwati22@gmail.com
+6281283133327
31-40
Indonesia
Original Research
Oscillometry vs spirometry: A comparative study for early detection of airway obstruction in asthma
Maximum 25 words
Abstract Content
Impulse oscillometry (IOS) is increasingly recognized for its ability to detect small airway dysfunction earlier than spirometry. It also correlates more closely with asthma symptoms and control, and is easier to perform. Despite these advantages, direct comparisons between IOS and spirometry in routine clinical practice remain limited. This study aimed to compare the two modalities in adult asthma patients at Persahabatan Hospital.
We conducted a cross-sectional study involving adult patients with asthma recruited from the outpatient clinic at Persahabatan Hospital between June and December 2025. Each participant underwent both spirometry and impulse oscillometry. Airway obstruction was defined according to the 2021 ATS/ERS technical standard on interpretive strategies for routine lung function tests.
A total of 104 patients were included, with a mean age of 55.9 ± 14.28 years; most were female (76.9%). Spirometry identified airway obstruction in 48 patients (46.2%), whereas oscillometry detected obstruction in 66 patients (63.5%). Oscillometry showed fair agreement with spirometry for both airway obstruction (Kappa = 0.284; p = 0.002) and small airway obstruction (Kappa = 0.319; p = 0.001). Among those with normal spirometry, half showed obstructive patterns on oscillometry, suggesting its potential for earlier detection of airway obstruction. The X5 parameter demonstrated the best diagnostic performance, with a transformed cut-off > 0.2142 (equivalent to native X5 < –0.2142 kPa/L/s) yielding 68.8% sensitivity and 71.4% specificity. The R5–R20 parameter (cut-off > 0.225) also showed potential for screening, with 66.7% sensitivity and 62.5% specificity.
Impulse oscillometry complements spirometry by detecting earlier airway obstruction in asthma, particularly in those with normal spirometric findings. It may serve as a useful adjunct for identifying early physiological changes.
 
 
 
 
 
No
No
 
JPG or JPEG or PNG format ONLY
impulse oscillometry, spirometry, small airway obstruction
maximum 3 keywords and no abbreviations, separated by commas
 
280