Suresh Anantharaj * Dr Rela Institute and Medical Centre Pulmonary Medicine Chennai India
Hemalatha Ramachandran - Kanchi Kamakoti Childs Trust Hospital Medical Statistics Chennai India
Joshika Suresh - Sree Balaji Medical College and Hospital Medicine, Surgery and OBG Chennai India
 
 
 
 
 
 
 
 
 
 
 
 
Presenting Author Details
Suresh
Anantharaj
suramya95@gmail.com
+919677001686
51-60
India
Original Research
Short-Term Variability in Airwave Oscillometry Among Adult Asthmatics: A Preliminary Investigation
Maximum 25 words
Abstract Content
Airwave Oscillometry(AOS) is under evaluation for diagnosis of asthma. Its simplicity makes it better suited for monitoring changes over time like Peak Expiratory Flow Rate (PEFR), and this needs further evaluation. The objective of the study is to assess Between-Day (BD) and Within-Day variability (WD) in AOS parameters among adult asthmatics.
Asthmatic and normal subjects underwent baseline investigations. PEFR and AOS were measured in the morning (AM) and evening (PM) for at least seven days within ≤2 weeks. For each subject, coefficients of variation (CVs) were calculated for Within-Day and Between-Day variability. WD CV was obtained by averaging daily AM–PM CVs over seven days. BD CV was calculated as the mean of AM and PM CVs across days. Mean CVs of the two groups were then compared.
We recruited 10 females comprising 5 asthmatics (off inhalers: mean ACQ6-1.21) and 5 normal subjects: mean ages 28.8 and 26.4 years respectively. No significant differences were found in baseline parameters between two groups (P>0.05). Mean CVs of WD values of PEFR, R5, R20, X5 and Ax were 2.64, 4.83, 6.92, -7.93, 15.84 and 6.71, 8.70, 8.02, -15.88, 22.89 respectively for normal subjects and asthmatics. Mean CVs of BD values of PEFR, R5, R20, X5 and Ax were 3.79, 7.10, 8.39, -13.15, 23.62 and 12.29, 13.98, 12.98, -20.16, 30.18 respectively for normal and asthmatics. Using WD cut-offs (CV 10; −10 for X5), X5 was positive in 4/5 asthmatics vs 1/5 normal, and R5 in 2/5 asthmatics vs none. Using BD cut-offs (CV 15; −15 for X5), X5 was positive in all asthmatics vs 2/5 normal, while R5 was positive in 2/5 asthmatics vs none. Ax showed limited discrimination between groups.
This preliminary investigation shows better short-term variability in AOS parameters (especially X5 and R5) among adult asthma patients, when compared to normal subjects.
 
 
 
 
 
No
No
 
JPG or JPEG or PNG format ONLY
variability, asthma, oscillometry
maximum 3 keywords and no abbreviations, separated by commas
 
331