APSR2026-46

 
Late-Breaking
Submitted
Oral Presentation
AO35-002
 
 
https://storage.unitedwebnetwork.com/files/1285/1200172-46903-APSR26_APSR AO35-002_431266.pptx
Format: PPTX Only
 
Format: PDF Only
14. Respiratory Structure and Function
3

No more than 15 authors can be listed.
Please ensure the authors are listed in the right order.
If there are multiple affiliations, please use the "+" button next to "Select Country/Region" to add additional affiliation fields.

Wang Chun Kwok * The University of Hong Kong Department of Medicine Hong Kong Hong Kong
James Chung Man Ho - The University of Hong Kong Department of Medicine Hong Kong Hong Kong
Terence Chi Chun Tam - The University of Hong Kong Department of Medicine Hong Kong Hong Kong
 
 
 
 
 
 
 
 
 
 
 
 
Presenting Author Details
Wang Chun
Kwok
kwokwch@hku.hk
+85290915898
31-40
 
Original Research
High degree of correlation for lung function parameters measured by Electrical Impedance Tomography and spirometry
Maximum 25 words
Abstract Content
Spirometry is currently the gold standard for assessing lung function; however it has notable limitations, including its inability to measure the regional lung function and discomfort associated with the effort required during testing. Electrical impedance tomography (EIT) has been studied primarily in mechanically ventilated critically ill patients, but its role to measure spirometric values in spontaneously breathing individuals remains insufficiently validated.
A prospective cross-sectional study was conducted in Queen Mary Hospital, Hong Kong from 1st October 2022 to 30th November 2024. Patients with or without respiratory diseases who attended scheduled spirometry were recruited to compare and correlate the lung function parameters measured by EIT and conventional spirometry.
A total of 135 of patients were included in the analysis, comprising 97 patients with respiratory diseases and 38 controls. Among patients with respiratory diseases, the correlation of FEV1 and FVC (in Litres) between spirometry and EIT measured by Pearson correlation coefficient (r) were 0.734 (95% CI = 0.626 – 0.814) and 0.692 (95% CI = 0.572 – 0.784) respectively, with both p-values < 0.001 (Fig. 1). Among controls without respiratory diseases, the correlation were r = 0.856 (95% CI = 0.739 – 0.923) for FEV₁ and r = 0.820 (95% CI = 0.678 – 0.903) for FVC.
EIT demonstrated a high degree of correlation with spirometry for key lung function parameters (FEV1 and FVC) in both patients with or without respiratory diseases. These findings suggest that EIT has the potential to sever as a non-invasive, effort-independent tool for lung function assessment across various patient groups.
 
 
 
 
 
Yes
Yes
https://storage.unitedwebnetwork.com/files/1285/1200172-37089-EITAPSR1_363570.jpg
JPG or JPEG or PNG format ONLY
Electrical impedance tomography, spirometry, lung function